Sprinkler System

A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically only used in factories and large commercial buildings, systems for homes and small buildings are now available at a cost-effective price.[1] Fire sprinkler systems are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings completely protected by fire sprinkler systems, over 96% of fires were controlled by fire sprinklers alone.

UL/FM Upright Sprinkler

Upright Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. Sprinkler is UL Listed and FM Approved. During fire, the heat-sensitive liquid in the glass bulb expands, causing the glass bulb to shatter. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern in order to control or extinguish fire.

  • Standard and quick response with standard coverage
  • Upright mounting
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom color finish
  • UL Listed and FM Approved

Specifications

UL/FM Sidewall Sprinkler

Sidewall Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. Sprinkler is UL Listed and FM Approved. During fire, the heat-sensitive liquid in the glass bulb expands, causing the glass bulb to shatter. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern in order to control or extinguish fire. Horizontal sidewall sprinkler are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling.

  • Standard and quick response with standard coverage
  • Sidewall mounting
  • Temperature rating : 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom color finish
  • UL Listed and FM Approved

Specifications

UL/FM Sidewall Sprinkler

  • O.D.: Φ33.7—Φ219.1 (mm)
  • Wall thickness: 2.75—5.0 (mm)
  • Anticorrosive: 1. hot galvanized; 2. powder coating; 3.painting
  • End state: 1.Grooved; 2. Plain end; 3.screwed & socketed
  • Function: Fire and water supply system in building

Specifications

Need Help with Fire Fighting Equipment? We Are Experts!