Hydrant Valves

A fire hydrant is simply a valve-like device similar in function to your water tap that provides constant water flow when you open it. Firefighters connect their water hose to that big valve that provide pressurized water flow (normally at 65 psi) to fight a fire.

UL/FM Pressure Relief Valve

Specifications

  • Certificate: UL Listed/ FM Approved
  • Standard: NFPA 20
  • Connection: Flanged as ANSI B16.42/ Thread
  • Pressure rating: Max 250 psi/ 400 psi
  • Adjustment: 20-200 psi/ 100-300 psi

UL/FM Flow Meter

Specifications

  • Centerline Type
  • Working Pressure: 300PSI(21Bars)
  • Working Temp: -20degree centigrade~110degree centigrade(-4° F~230° F)

UL/FM Single Butterfly Valve

Structure

UL Wafer Type Butterfly Valve

Specifications

  • U.L. Listed
  • Working Press. : 300 psi, & 175 Psi
  • Max.Test Press. : 600 psi & 350 Psi
  • Working Temp. : 250*F (120*C)
  • Factory Installed UL Approved Tamper Switch.
  • Body Ductile Iron, Nylon-11 Coated.
  • Disc AL-Bronze, Ductile Iron, EPDM Encapsulated
  • Stem Stainless Steel, Hardened & Tempered
  • Sizes: 2½”, 3″, 4″, 6″ , 8″, 10 “, 12”

UL Grooved Check Valve

Specifications

  • UL Dual Plate -Grooved End Check Valve – Ductile Iron Body with EPDM Seat
  • Working Pressure 300 PSI
  • All grooved dimensions comply with AWWA C606 standard.
  • Also available in flanged end configuration.
  • UL Dual Plate check valves may be installed in horizontal positions or vertical with flow moving up .
  • UL Dual Plate check valve reduces noise for quiet operation. Check valves prevent backflow by automatically closing when fluid reverses direction. The check valve is recommended for automatic fire sprinkler applications where space is a premium.
  • Size: 2″ -12″

UL/FM Gate Valves - 300 PSI

Specifications

UL/FM OS&Y Type Gate Valves

Specifications

  • Connections: Flanged (ANSI B16.1 Class 125)
  • Sizes: 2-1/2″ , 3″ , 4″ , 5″ , 6″ , 8″ , 10″ , 12″
  • Approvals: UL, ULC, and FM
  • Max. Working Pressure: 300 PSI
  • Max. Working Temperature: 180°F (82°C)
  • Type: Resilient Wedge, Outside Stem & Yoke
  • Finish: Epoxy Coated Interior and Exterior
  • Pre-Grooved Stem for Supervisory Switch
  • Specifications: Design and Dimensions Conform to AWWA C515

UL Alarm Check Valves

Specifications

  • Alarm Check Valve is of 8 Types:
  • 1.3” Flange/Groove Alarm Check Valve
  • 2.4” Flange/Groove Alarm Check Valve
  • 3.6” Flange/Groove Alarm Check Valve
  • 4.8” Flange/Groove Alarm Check Valve

UL/FM Swing Check Valves

Specifications

  • Ductile and Cast Iron Products
  • Sizes: 2″ – 12″
  • Pressure Rating: 300 PSI UL/FM
  • Working Temperature: 42ºF – 180ºF
  • Flanged: ANSI B16.7
  • Class 125
  • Meets AWWA C508

UL/FM Grooved Y-Type Strainer

Specifications

UL/FM Flanged Y-Type Strainer

Specifications

Grooved Pipe Fittings

Specifications